The CLETEF-786 Infrared Thermometer is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the CLETEF-786 Infrared Thermometer can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment. Irt207, Heat seeker, Infrared thermometer. Read online or download PDF. General Tools and Instruments IRT207 User Manual.
Advertising
1. Introduction
Congratulations on your purchase of the new IRT207
Heat Seeker
TM
InfraRed Thermometer (IRT). This IRT is
an 8:1 non-contact temperature measuring instrument
using infrared technology and laser sighting. Features include a 4 digit backlit LCD, scan/hold function and auto power off (7 secs). To measure a temperature, point the unit at the object, pull the measuring trigger and hold. Make sure the target area is larger than the unit’s spot size.
2. Safety Information
CAUTION: Use of controls or adjustments or
performance of procedures other than those specified herein may result in dangerous radiation exposure.
• DO NOT submerge the unit in water.
• This product is not designed for use in medical
evaluations. The product can only be used to
measure body temperature simply for reference. The IRT is meant for industrial and commercial uses.
LASER WARNING NOTE!
Do not point laser directly at eye.
Use caution around reflective surfaces. Keep out of reach of children.
This instrument conforms to the following standards:
EN61326: Electrical equipment for measurement, control
and laboratory use.
IEC61000-4-2: Electrostatic discharge immunity test.
IEC61000-4-3: Radiated, radio-frequency,
Winrar. Is good as RAR and ZIP extractor, also supports many formats to create an archive.B1 Free Archiver lacks at compression formats (only ZIP and the less known B1 format), but it has a decent speed.
electromagnetic field immunity test.
IEC61000-4-8: Power frequency magnetic field immunity
test.
Tests were conducted using a frequency range of
80-1000MHz with the instrument in three orientations. The average error for the three orientations is ±1.0ºF (±0.5ºC) at 3V/m throughout the spectrum. However, between 781-1000MHz at 3V/m, the instrument may not meet its stated accuracy.
3. Specifications
4. Operation of Instrument
4-1 Quick Start
To measure a temperature, point the unit at the target you
want to measure, pull the trigger and hold. Move closer to or farther from the target until it appears about the same size as the laser’s circular measurement ‘spot’, which has a D:S ratio (Field of View) of 8:1. The single spot of laser is used for aiming purposes only. The unit displays temperatures in either ºF or ºC. Replace the battery when the battery voltage drops below the voltage for reliable operation and the low battery symbol
appears.
Temperature Range
-4º to 608ºF (-20º to 320ºC)
Accuracy
±2% of reading or 3.6°F (2°C),
whichever is greater
Field of View
8:1
Laser Type,
Class 2, <1mW @655nm
Output/Wavelength
Repeatability
±1ºC (±1.8ºF)
Response Time
500 ms.
Operation Temp.
32º to 104ºF (0º to 40ºC) @ 10 to 90% RH
Auto Power Off
Automatically after 7 sec.
Emissivity
Fixed at 0.95
Storage Temp.
14º to 122ºF (-10º to 50ºC)
ºF/ºC Switchable
YES
Backlight
YES
Cen Tech Infrared Thermometer Reset
Laser Sight Switchable YES
Battery Type
Playin tv carrot mania download. Description:s60 2ndThe brand new version of Playin'TV's hit with more carrots, more enemies, 100 wild levels and even more fun! A game you just can't miss!Thanks to simple but addictive gameplay mechanisms, cartoonish characters and a progressive difficulty throughout 100 levels, Carrot Mania on Ice targets both casual players and gamers.
“9V” battery (included)
Battery Life
16 hrs
Dimension
5.98 x 4.65 x 1.26 in. (152 x 118 x 32 mm)
Weight
4.22 oz. (120g) without battery
Accessory
“9V” battery, Instruction manual
5. Maintenance
Forehead Thermometer Instructions
Cleaning the lens: Blow off loose particles using clean
compressed air. Gently brush remaining debris away with a camel’s hair brush. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water.
NOTE:
DO NOT use solvents to clean the glass lens.
Cleaning the housing:
Use soap and water on a damp sponge or soft cloth.
Battery Low
Temperature Display
SCAN
ºF/ºC Switch
Laser ON/OFF Indication
Infrared Thermometer Instruction Manual
ºF/ºC Switch Indication Amazon facial recognition software.
HOLD
Arrow Temp Thermometer Instructions
Laser ON/OFF Switch
IRT207
Heat Seeker
TM
Infrared Thermometer
©2014 GENERAL TOOLS & INSTRUMENTS New York, NY 10013
Montreal, Canada H9R 1E1
Laser Certification Label
(on side of unit)
Advertising
Popular Brands
Hygiplas Infrared Thermometer User Manual
Popular manuals
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |